Stove manufacturer s owners manuals should be checked for possible reductions.
Floor clearance wood stove.
6 of air space between woodstove bottom and floor protection system.
These wall protection measurements can be reduced with the proper wall protection.
Does a stovepipe need special clearance to combustibles.
Safe clearances for your model were determined using a very specific and detailed u l.
Any area within 36 inches of the wood stove should be covered as shown in figure 2.
18 in front of the woodstove.
The other is proper materials a properly installed and maintained wood stove can be one of the safest appliances in your home.
Other combustibles other combustible materials such as firewood paper curtains and plastics should be kept at least 36 inches from the stove.
Wood stove heat shields fire clearance distance reduction using heat shields how to install a wood stove or pellet stove heat shield.
We all want our wood stove installation to take up as little floor space as possible so the reduction of minimum clearances using special shields is common.
Clearance should be three times the diameter of the pipe e g a 6 inch pipe needs 18 inches of clearance.
The common feature of the clearance reduction rules is the air space behind the shield material.
Reducing minimum clearances safely.
The stove board was spaced 2 off of the floor 1 1 2 off of the wall and had several feet of clearance at either side and at the top so that air can circulate freely behind the board by convection.
Canadian standards cited below recommend the following floor protection.
We all want our wood stove installation to take up as little floor space as possible so the reduction of minimum clearances using special shields is common.
Using a piece of 24 gauge sheet metal installed on spacers 1 from an existing wall and floor will reduce stove clearances by 66 or from 36 to 12.
Clearances are measured from the outer surface of the appliance to the combustible material.
Clearances far stove and stovepipe from walls and floor.
Examples of combustible materials include paneling wood sheet rock even fire rated and plaster lathe.
Some codes permit 12 clearance from the side of the wood stove to the edge of the floor protection.
Advertisement if your walls are combustible you can install a shield on a wall to reduce the stove s clearance area.
The clearances for un certified stoves can be reduced safely using the rules set out below.
The wood heat organization recommends setting the floor pad so that it s flush with the surrounding flooring you don t want to remove a fire hazard but create a tripping hazard.
Stovepipes like fireplaces wood burning stoves must be vented to the outside of the building.
A clearance is the safe distance from the stove to a combustible surface.