Fan Limit Switch Temperature Settings

Honeywell L4064b Combination Fan And Limit Control How To Set The Temperatures And Limits On The Furnace Fan Limit Switch Control

Honeywell L4064b Combination Fan And Limit Control How To Set The Temperatures And Limits On The Furnace Fan Limit Switch Control

Honeywell L4064b Fan Limit Switch Setting Q A On Limit Control Adjustment Settings Repair

Honeywell L4064b Fan Limit Switch Setting Q A On Limit Control Adjustment Settings Repair

Test And Replace The Fan Limit Switch On A Furnace Hvac How To

Test And Replace The Fan Limit Switch On A Furnace Hvac How To

Other Automatic Controls Combination Fan And Limit Control Hvac Machinery

Other Automatic Controls Combination Fan And Limit Control Hvac Machinery

Fan Limit Control Installation Faqs

Fan Limit Control Installation Faqs

How To Install Wire The Fan Limit Controls On Furnaces Honeywell L4064b All White Rodgers Fan Limit Controllers

How To Install Wire The Fan Limit Controls On Furnaces Honeywell L4064b All White Rodgers Fan Limit Controllers

How To Install Wire The Fan Limit Controls On Furnaces Honeywell L4064b All White Rodgers Fan Limit Controllers

Open up the access panel on the furnace.

Fan limit switch temperature settings.

The the low limit is 80f. A high limit setting which turns off the heat source or burner. Range at the bottom. Slide the cover off the control switch.

What are the correct temperature settings for a fan limit switch. It should be located near the top of. How to set a fan limit control switch step 1. This switch may have to be fine tuned to keep the fan from coming on during summer and to keep the fan from short cycling during normal operation.

And the high limit is 130f. It is a round silver tin disc with a temp. An adjustable fan limit controller typically is designed for furnaces operating at temperatures from 100 f to 250 f has a fan off lower limit that can be adjusted from 50 f to 200 f a fan on switch adjustable from 65 f to 215 f and a fan high limit stop set at 200 f. My guess is 205f.

Jul 24 2007 10 06 am the limit switch would be set about 180 degrees this is the off temp the fan switch would be set to come on at 135 and go off at 100 to 105 degrees. Is the he limit. Most slide off or unhook for easy access. An on off switch for the blower fan.

A temperature sensor within the furnace. Look for the fan limit control switch encased in a small rectangular box.

Honeywell Furnace Temperature Fan Limit Switch Control Heating

Honeywell Furnace Temperature Fan Limit Switch Control Heating

Fan Limit Switch Faqs 4 Q A On How To Install Wire Set Or Fix The Furnace Fan Limit Control

Fan Limit Switch Faqs 4 Q A On How To Install Wire Set Or Fix The Furnace Fan Limit Control

Furnace Fan Limit Switch How Does A Fan Limit Switch Work How To Set Or Fix A Fan Limit Control

Furnace Fan Limit Switch How Does A Fan Limit Switch Work How To Set Or Fix A Fan Limit Control

Gas Furnace High Temperature Limit Problems Gray Furnaceman Furnace Troubleshoot And Repair

Gas Furnace High Temperature Limit Problems Gray Furnaceman Furnace Troubleshoot And Repair

Source : pinterest.com